-UV-8000/8000A/8000S Spectrophotometer-
Usage:
UV-8 Series are advanced double beam design consisting of 3 models: UV-8000, UV-8000A, UV-8000S. All the 3 models are Stand-alone models: UV8000 with 1.8nm fixed bandwidth, UV-8000A with 1nm bandwidth and UV-8000S with 0.5/1.0/2.0/4.0nm variable bandwidth. Except bandwidth, other specifications of the 3 models are almost the same.
The two detectors are measuring sample and reference respectively simultaneously for optimizing measurement accuracy.
LOCAL FIRMWARE FUNCTIONS:
All software methods are included as built-in standard, thus eliminating the need for software options. Online software upgrade via Internet helps to keep your software up-to-date.
The local control software include functions as: Basic Mode, Quantitative, Wavelength Scan, Kinetics, DNA/Protein, Multi- wavelength Test and System Utilities.
Standard Curve
Up to 10 standard solutions may be used to establish calibration equation curve. There is a choice of four methods for fitting a curve through the calibration points: Linear fit, Linear fit through zero, square fit and cubic fit.
Wavelength Scan
The wavelength scan intervals are 0.1, 0.2, 0.5, 1, 2, 5nm, and Hi, Medium and Low scan speeds are available. Scan speeds vary from 100 to 1000nm/min. Wavelengths are scanned from high to low so that the instrument waits at high wavelength. This minimizes the degradation of UV sensitive samples. Precise control of filter and lamp changes means that their effects are not seen on the final scan. Post-run manipulation includes re-scaling axes, curve tracking and peak picking.
Kinetics
This mode may be used for time course scanning or reaction rate calculations. Abs. vs. time graphs is displayed on the screen in real time.
Wait time and measurement time up to 12 hours may be entered with time intervals of 0.5,1, 2, 5, 10, 30 seconds and 1 min.
Post-run manipulation includes re-scaling, curve tracking and selection of the part of the curve required for the rate calculation. Rate is calculated using a linear regression algorithm before multiplying by the entered factor.
Multi-Wavelength
Up to 10 wavelengths may be entered, allowing the measurement
of multiple wavelengths on a series of Samples.
DNA/Protein Test
Concentration and DNA purity are calculated:
Absorbance ratios 260nm/280nm or 260nm/230nm with optional subtracted absorbance at 320nm
DNA Concentration=62.9 x A260 - 36.0 x A280
or 49.1x A260 - 3.48x A230
Protein Concentration=1552 x A260 - 757.3 x A280
or 183 x A260 - 75.8 x A230
Other wavelengths and factors may be entered.
PC SOFTWARE--UV/Vis Analyst For UV-6000 & UV-8000 Series
Specifications:
Model UV-8000 UV-8000A UV-8000S
Optical System Double Beam (1200 Lines/mm Grating)
Wavelength Range 190-1100nm
Band Width 1.8nm 1nm 0.5nm/ 1.0nm/ 2.0nm/ 4.0nm
Wavelength Accuracy ±0.3nm
Wavelength Repeatability 0.2nm
Photometric Accuracy ±0.3%T
Photometric Repeatability 0.2%T
Photometric Display Range 0-200%T, -0.3-3.0A, 0-9999C
Stability 0.001A/h @ 500nm
Baseline Flatness ±0.001A
Noise ±0.001A
Stray Light �.05%T @220nm, 360nm
Data Output Port USB
Printer Port Parallel Port
Display LCD (320*240 Dots )
Lamps Deuterium Lamp
& Tungsten Halogen Lamp
Detector Silicon Photodiode
Software Optional
Dimension (L*W*H) 625*430*206mm
Weight 30kg