-MODEL DC-3000C SERIES ULTRASONIC THICKNESS GAUGE-
Features:
?The through-Coating thickness Measurement (Echo-Echo)
?Automatic probe zero calibration
?Automatic probe identify
?Limited setting and alarm
?Varies measurement modes: transmit-echo, echo-echo, scan
●Gain adjustable
?Large memory up to 5000 group readings (3020C)
?USB output to PC
Technical Specification:
Specification DC3000C DC3020C
Measurement mode
Transmit –echo
-Standard measurement: For Normal thickness measurement.
-Minimum measurement: For curved surface
-Differential measurement: Displays the difference from the actual thickness
-measurement and a user entered reference value Average measurement : 2-9 point selectable
-Limit measurement: Min. Max setting and alarm ??br />
Echo-Echo The metal wall thickness is accurately and quickly measured in spite of surface
coating ??br />
Scan thickness value at 10 measurements per second while also
display actual thickness (Ideal for high temp. thickness readings) ??br />
Probe identify Auto ??br />
Probe zero Auto at power up and continuously during the measurement ??
Gain adjust
Auto gain adjustment
Manual gain adjustment, low, standard and high ??
Memory 5000 groups -- ?
Output USB to PC -- ?
Measuring Range 0.65-400mm (0.025-15.748inch) (range depends on probe-material combination) ??br />
Resolution 0.01mm (0.001 inch) for thickness up to 99.99mm
0.1mm ( 0.01 inch) for thickness above99.99mm ??
Information Display Measurement reading, Probe type, Velocity, measurement mode, measurement Symbol, Battery ??
Velocity range 9 material velocities are stored for selection, or entre the new velocity manually (1000m/s-9999m/s) ??
Velocity measurement Simply calibrate when a material’s velocity is unknown ??
Display 128 x 64 graphics LCD monochrome ??br />
Battery Type 2 AAA Alkaline ??
Battery life Up to 50 Hours (without Backlight) ??
Shut off Auto, 2Min., 5Min., or never shut off delectable ??br />
Working Temperature -20?50???
Unit mm/inch ??
Dimensions 115mm x 64mm x 27mm ??
Weight 220g ??
Specification for optional transducer:
Model Frequency Measuring range Diameter Temperature
D5301 5.0MHz T-E 0.8-300mm
E-E 4-25mm Ø10.8 ?0?
D5008 5.0MHz 0.8-300mm Ø10.8 ?0?
D5113 5.0MHz 3.0-200mm Ø13 <350?
D7006 7.5MHz 0.7-50mm Ø8.5 ?0?
D7004 10.0MHz 0.65-20mm Ø5 ?0?
D2012 2.0MHz 2.0-400.0mm Ø16.3 ?0?
Standard Delivery:
?Main unit
?Standard 5MHz transducer D5301
?Operation manual
?Two AAA batteries
?Built-in calibration block
?Software and Cable (3020C)
?Carrying case
?Couplant